LA12

LA12

  • Max Thrust: 750N
  • Max Speed: 40mm/s
  • Stroke Length: 19-130mm
LA14

LA14

  • Max Thrust: 750N
  • Max Speed: 45mm/s
  • Stroke Length: 19-130mm
LA25

LA25

  • Max thrust: 2,500N
  • Max Speed: 25mm/s
  • Stroke Length: 20-300mm
LA33

LA33

  • Max thrust: 6,000N
  • Max Speed: 15mm/s
  • Stroke Length: 100-600mm
LA36

LA36

  • Max thrust: 10,000N
  • Max Speed: 160mm/s
  • Stroke Length: 100-999mm
LA37

LA37

  • Max thrust: 15,000N
  • Max Speed: 3.5mm/s
  • Stroke Length: 100-600mm

Function Test

Climatic Tests :

In the climatic test the actuator are tested to operate in extreme temperature as well as to endure rapid changes in temperature, In Some tests, the actuator has to withstand going from a +100 deg C environment To 30 deg C repeatedly and still maintain full functionality

Mechanical Tests :

Vibration:The actuator must withstand continuous vibration in three direction

Shock: The shock test puts the actuator through 3 shocks of uo to 100 G in each of six direction

Bumps: The actuator receives bumps of up to 40 G in each of six direction several hundred times

Electric Test:

All the electric parts are tested i.e power supply, power and signal cables, Control Signals etc. Electrical immunity is tested according to industrial standards i.e for radio noise, electrical discharge and burst.

Application

Extreme testing